XC9502 Series

2ch. Step-Up / Step-Down DC/DC Controller

The XC9502 series are PWM controlled, PWM/PFM automatic switching controlled, multi-functional, 2 channel step-up and down DC/DC controller ICs. With 0.9V of standard voltage supply internal, and using externally connected components, the output 1 voltage (step-up DC/DC controller) can be set freely within a range of 1.5V to 30V. Since the output 2 (step-down DC/DC controller) has a built-in 0.9V reference voltage (±2.0%), 0.9V to 6.0V can be set using external components.

With a 180kHz frequency, the size of the external components can be reduced. Switching frequencies of 300kHz & 500kHz are also available as custom-designed products.

The control of the XC9502 series can be switched between PWM control and PWM/PFM automatic switching control using external signals. Control switches from PWM to PFM during light loads when automatic switching is selected and the series is highly efficient from light loads through to large output currents.

Noise is easily reduced with PWM control since the frequency is fixed. The series gives freedom of control selection so that control suited to the application can be selected. Soft-start time is internally set to 10ms (Output 1) and offers protection against in-rush currents when the power is switched. This also prevents voltage overshoot.

Typical Application Circuit

Features

2chDC/DC Controller Output1 : Step-up DC/DC Controller
Output2 : Step-down DC/DC Controller
Output Voltage Range 1.5V~30.0V,Can be set freely with 0.9V (±2.0%) of reference voltage supply and external components.
0.9V~6.0V,Can be set freely with 0.9V (±2.0%) of reference voltage supply and external components.
Output Current Step-Up:≦~300mA(VIN=1.8V,VOUT=3.3V)
Step-Down:≦1000mA(VIN=3.3V,VOUT=1.8V)
Stand-by Current 3.0μA(MAX)
Power Supply Voltage Range 2.0V~10V
Oscillation Frequency 180kHz±15%, 300kHz、500kHz are available as custom
Soft-Start 10ms(intemallyset)

Packages

Package USP-10 Number of Pins 10
Pcs/Reel 3,000 Package Size(mm) 2.5 x 2.7 x 0.6

DATA SHEET

Quality Reports

FAQ

QuestionWhat does the standby mode mean in the case of the multi channel IC?
Answer

It means the state where the entire IC has been turned off. For Torex products, it means that the pin voltages of EN1 and EN2 are both 0V.

QuestionHow does the GO function of DC/DC converters work? Does it work just like a regulator?
Answer

Torex regard the PWM/PFM automatic switch control function as Green Operation (GO) in the case of DC/DC. The GO function is defined as the switching operation between the PFM mode for a small output current and the PWM mode for a large output current. The PFM control method controls the output current by increasing and decreasing the fall time according to the output current while keeping a pulse width. The PWM control method controls the output current by adjusting the pulse width of the rise time, which keeps the rise/fall time interval constant and increases the efficiency at a heavy load. By switching between the PFM control for a small output current and the PWM control for a large output current, the quiescent current can be controlled for both of heavy and light loads.

QuestionWhat is the soft-start function?
Answer

The function to soften the rise to prevent the inrush current.

QuestionWhat is the standby current?
Answer

The current that flows through the IC in the standby mode. The standby mode means the state where the IC has been turned off by the CE function.